CellarPro 3400H-ECX Houdini Wine Cellar Cooling Unit #35856

(No reviews yet) Write a Review
$4,595.00

Free Shipping

Free shipping to lower 48 states only, otherwise, please call for additional pricing.
Reviews
Loading review.....
Description
  • Overview
  • Features
  • Tech Specs
  • Configurations
  • PDF Downloads
  • Reviews

cellarpro-logo.jpg

  • Cooling Capacity @ 55 F: 3492 BTUH
  • Dedicated Circuit: 15 Amp
  • Power: 115VAC/ 60Hz
  • Cooling Unit dBA: 56/61
  • Refrigerant: R134A

CellarPro 3400H-ECX Cooling Unit (P/N 35856). NOW WITH ENERGY-EFFICIENT EC FANS! CellarPro engineered the 3400H-ECX cooling unit specifically for shallow-depth glass wine cellars.

Just 13-inches deep and 14 1/2-inches tall, the 3400H-ECX Houdini cooling unit is designed to "disappear" inside - or atop - the cellar. Dual independent variable-speed fans offer flexibility to trade-off between super-quiet operation vs maximum performance.

♦ View more of our CellarPro Products

♦ Click to view more CellarPro Units

All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space - it must come from space outside the cellar.

Variable-speed fans with independent control provide maximum flexibility and versatility, as follows:

Variable fan speed for the cold side

  • Provides cooling flexibility
  • Low fan speed: 2737 BTUH @ 55F / 47F lowest achievable cellar temperature
  • High fan speed: 3492 BTUH @55F / 47F lowest achievable cellar temperature

Variable fan speed for the hot side

  • Choose between performance vs noise
  • Low fan speed: 56 dBA / 85F maximum intake temperature
  • High fan speed: 61 dBA / 95F maximum intake temperature

Powerful fans on the 3400H-ECX allow the cooling unit to be ducted without the need for an auxiliary fan, as follows:

Cold side:

  • Up to 100 equivalent feet (50' per duct) with 8-inch insulated ducting
  • Intake from the bottom, left, front, or top / exhaust from the bottom, front, or top

Hot side with 152.4mm ducting:

  • Up to 100 equivalent feet (50' per duct) and 85F maximum intake temperature (no auxiliary fan required)
  • Up to 200 equivalent feet (100' per duct) and 95F maximum intake temperature (requires auxiliary fan)
  • Intake from the right, front, or top / exhaust from the front, rear, or top

Ducting requires CellarPro duct equipment (sold separately)

Features

  • Features energy-efficient EC Fans on both the cold and hot sides
  • This unit can be configured to pull fresh air ranging from -20 to 95F. If the unit's location does not provide sufficient room for the unit's exhaust to dissipate and/or fresh air to be provided, you may need to purchase a rear duct kit. We recommend the addition of a fan cycling switch when fresh air intake will be below 20F.
  • The unit must be placed indoors in an area that is above 32F.
  • Dual high-output fans come with independent variable speed settings for your choice of maximum cooling power at the high fan speed, or super-quiet operation (56 decibels) at the low fan speed.
  • Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
  • Custom coils generate maximum cooling power inside the cellar.
  • Excess condensate is managed with a high-capacity stainless steel condensate pan and 200W electric heating element.
  • Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion.
  • Intuitive LED display panel mounted on the evaporator with digital programmable thermostat is simple and easy to use. Remote thermostat is available as an upgrade.
  • Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
  • Temperature set point range is 47F to 62F when the cooling unit is properly sized.
  • Unit operates with minimal vibrations and less noise than comparable units from competitors.
  • Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
  • With dual power sources and a 10-foot power cord, the unit can be plugged into a receptacle from either the rear or right side of the cooling unit, providing flexibility for most installations.
  • Common dedicated 15-amp circuit is required to power the unit.
  • Mounting brackets, included as standard equipment, ensure easy installation.
  • Removable steel case provides access to the internal components for servicing and repair.
  • CellarPro's 5-Year Standard Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
  • An optional Extended Warranty (P/N 31488) is available for additional protection.
  • ETL Tested and Certified to rigorous UL Standards for safety.
  • Model: 3400H-ECX
  • Cellar Size(Nominal Cu Ft)*: 900
  • Compressor Size (HP): 1/2 Ton
  • BTUH @ 55F(Low/High Evap Fan Speed): 2737/ 3492
  • CFM (Low/High Cond Fan Speed): 165/ 220
  • Cooling Unit dBA: 56/ 61
  • Installation Environment: Indoor
  • Ambient Intake Range: -20** to 95F
  • Power: 115V AC/ 60Hz
  • Amps (Starting/Running): 40/ 10.26
  • Dedicated Circuit: 15-Amp
  • Refrigerant: R134a
  • Drain Line: Optional -1/2" ID
  • Ducting - Cold Side: Optional –8" Diam.
  • Ducting - Hot Side: Optional –8" Diam.

Dimensions

  • Size (W x D x H -inches): 43 x 13 x 14.5
  • Weight (lbs): 107
  • CellarPro 3400H-ECX cooling units are self-contained, fully-charged units designed to be attached to the ceiling inside the cellar, or above the cellar.
  • 3400H-ECX units also can be located remotely from the cellar with the addition of one of our cold-side duct packages. Offered with or without insulated flex ducting, in a choice of configurations for low or high humidity conditions, our cold-side duct packages allow these cooling units to be ducted up to 50 equivalent feet away from the cellar and require 8-inch (or greater) ducting from start to finish.
  • When calculating equivalent feet, each 90-degree turn counts for 8 feet.
  • For remote or inaccessible installations, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar.
  • 3400H cooling units require fresh air intake without interference from the unit's hot air exhaust. If sufficient space does not exist to provide fresh air, you may need our hot-side duct kit.
  • The cold side of the cooling unit should never be exposed to temperatures below 32F.
  • A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.